American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist 17 flashes

What it should look like on your machine

then it repeats

17 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 80. The Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts lists seventeen flashes as a high pressure monitor fault, in a hard-lockout form reset by cycling power and a short-lockout form during which the comfort control shows Wait. It matters because the monitor is stopping the compressor for excessive refrigerant pressure - typically heat that cannot be rejected because of a fan or airflow failure, or an overcharge - and repeated trips risk compressor damage if the cause is ignored.

Likely causes

  1. Outdoor fan motor failure in cooling
  2. Indoor airflow restriction in heating, including a dirty air filter
  3. Refrigerant overcharge
  4. High pressure switch or monitor wiring fault

How to fix it — step by step

  1. Record the code before cycling power: count seventeen flashes, note the mode, and whether the comfort control shows Wait for the short-lockout form before cycling power. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: confirm the outdoor fan runs in cooling and check both coils and the indoor air filter for restriction
  4. Test: a technician with gauges confirms whether liquid pressure truly reaches trip levels; the Service Facts' Charge Assist notes use liquid pressure thresholds around normal operation, and pressure that stays normal while the fault sets points to the monitor switch or its wiring
  5. End point: restore fan or airflow faults - a tested-bad outdoor fan motor or run capacitor can be replaced. Overcharge correction and pressure-device work are sealed-system pro jobs; do not repeatedly reset the hard lockout. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.