American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist 5 flashes

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts lists five flashes as an ambient temperature sensor fault, out of range - open or shorted. The manual's notes stress that a working ambient sensor is needed for the low-pressure monitor, Charge Assist, defrost on heat pump models, comfort-control outdoor temperature display, auxiliary heat control during defrost, and compressor and auxiliary heat lockouts, so this one sensor failure degrades many functions at once.

Likely causes

  1. Ambient temperature sensor open or shorted
  2. Sensor resistance drifted out of range
  3. Damaged sensor wiring or connector at the outdoor control board
  4. Failed sensor input on the outdoor control board

How to fix it — step by step

  1. Record the code before cycling power: count five flashes and record ERR 67 before cycling power. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: the ambient sensor is located outside the outdoor coil and wired to the outdoor control board in the control box
  4. Test: power off, unplug the sensor and measure its resistance against the Service Facts temperature chart at the actual outdoor temperature - open, shorted or far off-chart readings confirm the fault; inspect the lead for damage on the way
  5. End point: replace a failed ambient sensor. If a known-good sensor still flashes five, the outdoor control board's sensor input has failed and board replacement is pro work. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist problems

See all American Standard 4A7A6048C1000B heat pump with AccuLink and Charge Assist codes & guides →