American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist 14 flashes
What it should look like on your machine
then it repeats
14 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 114. The Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts lists fourteen flashes for Personality Module faults: PM missing with a local copy, bad data in the PM with a local copy - both operational - and bad data or a missing PM with no local copy, which is not operational. The manual elsewhere warns the Personality Module contains model-specific information needed for system operation and must not be removed. It matters because without valid PM data the control does not know what equipment it is running.
Likely causes
- Personality Module missing, unseated or disturbed during service
- Corrupted data in the Personality Module
- Damaged PM connector or socket on the outdoor control board
- Wrong Personality Module fitted after a board or control change
How to fix it — step by step
- Record the code before cycling power: count fourteen flashes and record ERR 114, and note whether the system still operates - the chart separates operational local-copy cases from not-operational no-copy cases. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
- Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
- Locate the part: with power off, locate the Personality Module on the outdoor control board in the control box and check it is fully seated and has not been removed or swapped
- Test: reseat the module once and restore power; if fourteen flashes return, the manual's distinction applies - a unit running on its local copy still needs the module fault corrected, and a non-operational unit has no valid configuration to run on
- End point: a module that will not read correctly after reseating, or a damaged socket, is pro work: the correct model-specific Personality Module or control board must be fitted, not a substitute from another unit. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Control board.
Parts that commonly fix it
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist problems
- 17 flashes
- 18 flashes
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- ERR 90
- 1 flash
- 10 flashes
- 11 flashes
See all American Standard 4A7A6048C1000B heat pump with AccuLink and Charge Assist codes & guides →