American Standard Heat pump 4A6H7024A1000C split system heat pump EEV board 6 flashes

What it should look like on your machine

then it repeats

6 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Read on the red Fault LED of the Electronic Expansion Valve control board in this American Standard heat pump, Table 6 in the Service Facts. Six flashes means the valve is not responding to a position change command - a possible stuck valve. The manual notes faults 6 through 9 are stored in non-volatile memory and are cleared by the Close Valve Test jumper procedure, not by a simple power cycle. It matters because the outdoor EEV controls superheat in heating mode; a valve that will not move leaves the system pumping down, flooding, or starving depending where it is stuck.

Likely causes

  1. EEV stuck mechanically
  2. EEV coil or harness failure preventing the valve driving
  3. Suction temperature or pressure inputs misleading the EEV control
  4. Failed EEV control board drive output

How to fix it — step by step

  1. Record the code before cycling power: count six flashes on the EEV board's red Fault LED and remember this fault is stored - note it before attempting the manual's clearing procedure. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: the EEV board is in the outdoor unit; its Open and Close valve tests are run from the TEST, OPEN and CLOSE pins described in the Service Facts
  4. Test: run the manual's Open Valve Test: the status LED flashes while the valve drives, and a temperature probe should show superheat falling if the valve moves; no response supports the stuck-valve or drive-failure reading. Verify the suction sensors against Tables 1 and 2 before condemning the valve
  5. End point: a valve that provably will not move is sealed-system pro work. A failed EEV control board drive, proven with good sensors and coil, can be replaced by a technician; clear stored faults only by the manual's Close-Test jumper procedure after repair. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related American Standard Heat pump 4A6H7024A1000C split system heat pump problems

See all American Standard 4A6H7024A1000C split system heat pump codes & guides →