York Air Conditioner Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 18 problems covered.
Shop York Air Conditioner parts at RepairClinic or Amazon
All Air Conditioner codes across brands →
Not sure of the code? Tap along with it
If your York Air Conditioner blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your rhythm: -
Finding your model number: it is on the unit's rating plate.
- AC leaking water inside — York's owner's manual gives this symptom its own line — 'Wet on Floor' — and its own cause: the condensate drain and its 'P' trap, blocked…
- AC not cooling — York's owner's-manual troubleshooting table for 'no cooling' works through the control chain in order: thermostat setting too high, a blown…
- AC short cycling — York's manual describes this symptom as 'the compressor starts but shuts down quickly,' and its cause list is dominated by the sealed…
- AC won't turn on — York's troubleshooting guide for 'the air conditioner does not run' lists eight causes, and only the first few are homeowner territory…
- Condenser fan not spinning — York's cooling troubleshooting table treats 'compressor and condenser fan will not start' and a condenser fan that will not run as…
- Frozen evaporator coil — Ice on the refrigerant line or the indoor coil of a York system means the coil surface dropped below freezing — the moisture that should…
- LED1 1 flash, LED2 off — High-pressure switch fault (not in lockout yet) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (heat pump…
- LED1 1 flash, LED2 on steady — Compressor contactor miswire on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107…
- LED1 2 flashes, LED2 off — High-pressure switch lockout (last mode of operation was heat pump) on the YorkGuard VI demand defrost / outdoor unit control in a York…
- LED1 2 flashes, LED2 on steady — Y2 present without Y1 on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 7…
- LED1 4 flashes, LED2 off — Low-pressure switch lockout on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107…
- LED1 5 flashes, LED2 off — Low voltage (below 19 VAC) preventing further relay outputs, on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor…
- LED1 6 flashes, LED2 off — Low voltage (below 16 VAC) — voltage so low it has stopped the current relay outputs, on the YorkGuard VI demand defrost / outdoor unit…
- LED1 7 flashes, LED2 off — Pipe freeze protection timer expiration on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document…
- LED1 on steady, LED2 1 flash — Outdoor ambient sensor failure (short) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document…
- LED1 on steady, LED2 2 flashes — Outdoor ambient sensor failure (open) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document…
- LED1 on steady, LED2 3 flashes — Liquid line sensor failure (short) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document…
- LED1 on steady, LED2 5 flashes — High discharge line temperature on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit fitted with the optional…