York Air Conditioner LED1 2 flashes, LED2 off

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

High-pressure switch lockout (last mode of operation was heat pump) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 5). LED1 (red) flashes twice, LED2 (green) is off; the X/L output signals a soft lockout (2 flashes) or hard lockout (3 flashes) at the thermostat. Per the manual, soft lockout follows two high-pressure switch openings within six hours.

Likely causes

  1. Repeated high-pressure switch openings → Shop the high-pressure switch at RepairClinic
  2. Dirty outdoor coil, failed outdoor fan or overcharge driving head pressure up

How to fix it — step by step

  1. Clean the outdoor coil and confirm outdoor fan operation
  2. Have a technician measure head pressure and correct the cause; soft lockout resets by interrupting the thermostat call after the fault is corrected, hard lockout requires cycling power to the system

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related York Air Conditioner problems

See all York Air Conditioner codes & guides →