York Air Conditioner LED1 2 flashes, LED2 off
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
High-pressure switch lockout (last mode of operation was heat pump) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 5). LED1 (red) flashes twice, LED2 (green) is off; the X/L output signals a soft lockout (2 flashes) or hard lockout (3 flashes) at the thermostat. Per the manual, soft lockout follows two high-pressure switch openings within six hours.
Likely causes
- Repeated high-pressure switch openings → Shop the high-pressure switch at RepairClinic
- Dirty outdoor coil, failed outdoor fan or overcharge driving head pressure up
How to fix it — step by step
- Clean the outdoor coil and confirm outdoor fan operation
- Have a technician measure head pressure and correct the cause; soft lockout resets by interrupting the thermostat call after the fault is corrected, hard lockout requires cycling power to the system
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the High-pressure switch.
Shop the High-pressure switch at RepairClinic or Amazon
Also tied to this fault: Outdoor fan motor - Shop at RepairClinic or Amazon
Parts that commonly fix it
- High-pressure switch - Shop at RepairClinic or Amazon
- Outdoor fan motor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Air Conditioner problems
- LED1 2 flashes, LED2 on steady
- LED1 4 flashes, LED2 off
- LED1 5 flashes, LED2 off
- LED1 6 flashes, LED2 off
- LED1 7 flashes, LED2 off
- LED1 on steady, LED2 1 flash
- LED1 on steady, LED2 2 flashes
- LED1 on steady, LED2 3 flashes
- LED1 on steady, LED2 5 flashes
- AC leaking water inside
- AC not cooling
- AC short cycling