York Air Conditioner LED1 on steady, LED2 5 flashes
What it should look like on your machine
then it repeats
5 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
High discharge line temperature on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit fitted with the optional discharge line sensor (document 276251-UAI-A-0107, Table 6). LED1 (red) is on constantly and LED2 (green) flashes 5 times; per the manual's lockout section, a discharge temperature reading above 263°F causes a soft lockout, and the X/L output shows soft (2-flash) or hard (3-flash) lockout.
Likely causes
- Excessively high compressor discharge temperature
- Low refrigerant charge or high head pressure overheating the compressor
How to fix it — step by step
- Turn the system off and let the compressor cool → Shop the compressor at RepairClinic
- Have a technician check refrigerant charge and head pressure before resetting any lockout
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Discharge line temperature sensor.
Shop the Discharge line temperature sensor at RepairClinic or Amazon
Also tied to this fault: Compressor - Shop at RepairClinic or Amazon
Parts that commonly fix it
- Discharge line temperature sensor - Shop at RepairClinic or Amazon
- Compressor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number