York Air Conditioner Condenser fan not spinning
What this problem usually means
York's cooling troubleshooting table treats 'compressor and condenser fan will not start' and a condenser fan that will not run as electrical-chain problems: power failure or a tripped breaker first, then the thermostat, contactor, transformer and control relay, and faulty wiring. Elsewhere in the same table York names a faulty condenser-fan motor or capacitor behind excessive head pressure — which is exactly what a stopped fan produces, since the outdoor coil cannot shed heat. Expect the compressor to trip out on overload within minutes of running without the fan, so the pair of symptoms (fan still, then everything stops) is one fault, not two.
Likely causes
- Failed condenser fan motor → Shop the condenser fan motor at RepairClinic
- Failed fan capacitor
- Tripped breaker, blown fuse or power failure to the outdoor unit
- Defective contactor, transformer or control relay not sending power to the fan
- Loose or faulty wiring in the fan circuit
How to fix it — step by step
- Turn the system off at the thermostat once you confirm the fan is not spinning while the unit is trying to cool — running without the fan drives head pressure up and trips the compressor
- Verify the thermostat is calling for cool and the setpoint is below room temperature
- Reset a tripped breaker once; a repeat trip is a professional diagnosis, not a nuisance
- With power off, look for debris or a visibly damaged blade through the grille; do not reach inside the cabinet
- Stop and call a York contractor to test the fan motor, capacitor and contactor — the parts York's own table lists for this symptom → Shop the contactor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the condenser fan motor.
Shop the condenser fan motor at RepairClinic or Amazon
Also tied to this fault: run capacitor - Shop at RepairClinic or Amazon; contactor - Shop at RepairClinic or Amazon; fan blade - Shop at RepairClinic or Amazon
Parts that commonly fix it
- condenser fan motor - Shop at RepairClinic or Amazon
- run capacitor - Shop at RepairClinic or Amazon
- contactor - Shop at RepairClinic or Amazon
- fan blade - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Air Conditioner problems
- Frozen evaporator coil
- LED1 1 flash, LED2 off
- LED1 1 flash, LED2 on steady
- LED1 2 flashes, LED2 off
- LED1 2 flashes, LED2 on steady
- LED1 4 flashes, LED2 off
- LED1 5 flashes, LED2 off
- LED1 6 flashes, LED2 off
- LED1 7 flashes, LED2 off
- LED1 on steady, LED2 1 flash
- LED1 on steady, LED2 2 flashes
- LED1 on steady, LED2 3 flashes