York Air Conditioner LED1 6 flashes, LED2 off
What it should look like on your machine
then it repeats
6 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Low voltage (below 16 VAC) — voltage so low it has stopped the current relay outputs, on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 5). LED1 (red) flashes 6 times, LED2 (green) is off.
Likely causes
- Severely low 24 VAC supply to the outdoor control
- Failing transformer or a low-voltage short
- Bad low-voltage connection at the outdoor unit
How to fix it — step by step
- Turn off power and check low-voltage connections at the outdoor control
- Have a technician measure control voltage and find the short or failed transformer → Shop the control transformer (indoor, 40 va minimum) at RepairClinic
- Do not keep resetting the unit until control voltage is restored to normal
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Control transformer (indoor, 40 VA minimum).
Shop the Control transformer (indoor, 40 VA minimum) at RepairClinic or Amazon
Parts that commonly fix it
- Control transformer (indoor, 40 VA minimum) - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.