What this problem usually means

Outdoor ambient sensor failure (open) on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 6). LED1 (red) is on constantly and LED2 (green) flashes twice; the X/L output shows a soft-lockout signal. Per the manual, a shorted or open outdoor ambient sensor is also a wiring/setting lockout condition that stops compressor operation.

Likely causes

  1. Open outdoor ambient temperature sensor → Shop the outdoor ambient temperature sensor at RepairClinic
  2. Broken sensor wire or loose sensor connection

How to fix it — step by step

  1. Turn off power to the outdoor unit
  2. Check the ambient sensor connections at the control (AMB/AMBG terminals)
  3. Have a technician test and replace the sensor if open, then clear the fault memory