York Air Conditioner LED1 4 flashes, LED2 off

What it should look like on your machine

then it repeats

4 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Low-pressure switch lockout on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 5). LED1 (red) flashes 4 times, LED2 (green) is off; the X/L output signals a soft (2-flash) or hard (3-flash) lockout at the thermostat. Per the manual, one low-pressure switch opening of more than five seconds (outside the exempt conditions) can cause a soft lockout.

Likely causes

  1. Low refrigerant charge / refrigerant leak
  2. Low-pressure switch open for more than five seconds
  3. Low airflow or a restriction dropping suction pressure

How to fix it — step by step

  1. Replace a dirty indoor filter and confirm the indoor blower runs
  2. Have a technician check refrigerant pressures and test the low-pressure switch before resetting the lockout → Shop the low-pressure switch at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related York Air Conditioner problems

See all York Air Conditioner codes & guides →