York Air Conditioner LED1 2 flashes, LED2 on steady
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Y2 present without Y1 on the YorkGuard VI demand defrost / outdoor unit control in a York outdoor unit (document 276251-UAI-A-0107, Table 7 Wiring Related Fault Codes). LED1 (red) flashes twice while LED2 (green) is on constantly; the X/L output shows 4 flashes. The control will not operate the compressor while this wiring fault is present.
Likely causes
- Thermostat or indoor unit wiring error — second-stage Y2 signal without first-stage Y1
- Y1 wire open or landed on the wrong terminal
How to fix it — step by step
- Turn off power to the system
- Have a technician check the Y1/Y2 wiring at the thermostat, indoor unit and outdoor control against the wiring diagram
- Correct the wiring and cycle power to clear the fault
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable opening the machine up, a repair shop is the next step.
Parts that commonly fix it
No specific replacement part is documented for this fault. If the checks above do not clear it, the machine likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.