Lennox Furnace Residential Communicating Systems alert codes — EL296/SL280/SLP98/ML296 and similar E240 Error Code
What the E240 code means
On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E240 means low flame current in run mode — the flame sensor signal is weak while the burners run.
Likely causes
- Dirty or oxidized flame sensor
- Poor burner ground
- Exhaust recirculating into the intake at the termination
How to fix it — step by step
- Replace the air filter and open all registers
- Check that the outdoor exhaust is not blowing back into the intake termination
- Note if the furnace short-cycles
- Call a technician to clean or replace the flame sensor and measure flame current → Shop the flame sensor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the flame sensor.
Parts that commonly fix the E240 code
- flame sensor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.