Lennox Furnace Residential Communicating Systems alert codes — EL296/SL280/SLP98/ML296 and similar E227 Error Code

What the E227 code means

On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E227 means the low pressure switch opened in run mode — draft was proved, then lost while the furnace was running (seven-segment wording: pressure switch opened during ignition or run).

Likely causes

  1. Vent or intake blocked during run
  2. Condensate backing up during run
  3. Failing inducer motor → Shop the inducer motor at RepairClinic
  4. Intermittent pressure switch → Shop the pressure switch at RepairClinic

How to fix it — step by step

  1. Clear the outdoor terminations
  2. Check the condensate drain hose for clogs, kinks or freezing
  3. Reset power once and watch a full cycle
  4. Call a technician if it recurs, to test draft and the inducer

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E227 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.