Lennox Furnace G61MPV — SureLight single-LED paired-flash (X + Y) 4 + 1 Error Code

What the 4 + 1 code means

On Lennox G61MPV furnaces with the SureLight control, flash code 4 + 1 is a Watchguard lockout — the furnace exceeded the maximum number of ignition retries and will wait (about an hour) before trying again.

Likely causes

  1. Failed hot surface igniter → Shop the hot surface igniter at RepairClinic
  2. Dirty flame sensor
  3. Gas supply off or interrupted
  4. Blocked condensate drain preventing ignition sequence

How to fix it — step by step

  1. Note any earlier flash code, since Watchguard is the result, not the root cause
  2. Confirm the gas shutoff is open and the filter is clean
  3. Wait for the Watchguard period to end or reset power once
  4. If it locks out again, call a technician to test the igniter, flame sensor and gas valve → Shop the flame sensor at RepairClinic → Shop the gas valve at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 4 + 1 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Lennox Furnace G61MPV — SureLight single-LED paired-flash (X + Y) error codes

See all Lennox G61MPV — SureLight single-LED paired-flash (X + Y) codes & guides →