Lennox G61MPV — SureLight single-LED paired-flash (X + Y) Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 16 codes covered.
Shop Lennox G61MPV — SureLight single-LED paired-flash (X + Y) parts at RepairClinic or Amazon
- 1 + 2 — On Lennox G61MPV furnaces with the SureLight control, flash code 1 + 2 means low flame current in run mode — the flame signal is weak while…
- 1 + 3 — On Lennox G61MPV furnaces with the SureLight control, flash code 1 + 3 means flame sensed out of sequence — a flame signal is still present…
- 2 + 3 — On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 3 means the low pressure switch failed open — it did not close to…
- 2 + 4 — On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 4 means the low pressure switch failed closed — it was already closed…
- 2 + 5 — On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 5 means the high pressure switch failed open — the second-stage…
- 2 + 7 — On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 7 means the low pressure switch opened during the ignition trial or…
- 3 + 1 — On Lennox G61MPV furnaces with the SureLight control, flash code 3 + 1 means the limit switch is open — the furnace overheated and the high…
- 4 + 1 — On Lennox G61MPV furnaces with the SureLight control, flash code 4 + 1 is a Watchguard lockout — the furnace exceeded the maximum number of…
- 4 + 5 — On Lennox G61MPV furnaces with the SureLight control, flash code 4 + 5 is a Watchguard lockout — the limit switch remained open longer than…
- 4 + 7 — On Lennox G61MPV furnaces with the SureLight control, flash code 4 + 7 means an ignitor circuit fault — a failed ignitor or its triggering…
- 4 + 8 — On Lennox G61MPV furnaces with the SureLight control, flash code 4 + 8 means low line voltage — the supply voltage to the furnace is below…
- 5 + 1 — On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 1 is a hard lockout — the rollout circuit is open or was previously…
- 5 + 2 — On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 2 means the control failed its self-check — an internal control error.…
- 5 + 3 — On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 3 means no earth ground — the control does not detect a ground. The…
- 5 + 4 — On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 4 means reversed line voltage polarity. The G61MPV manual notes the…
- 5 + 6 — On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 6 means low secondary (24VAC) voltage — the low-voltage supply from…