Lennox Furnace G61MPV — SureLight single-LED paired-flash (X + Y) 5 + 1 Error Code

What the 5 + 1 code means

On Lennox G61MPV furnaces with the SureLight control, flash code 5 + 1 is a hard lockout — the rollout circuit is open or was previously opened. This is a safety lockout that will not auto-retry.

Likely causes

  1. Flame rollout from a blocked or cracked heat exchanger
  2. Blocked venting
  3. Tripped manual-reset rollout switch

How to fix it — step by step

  1. Turn the furnace off and leave it off
  2. Do not reset the rollout switch yourself — the cause must be found first → Shop the rollout switch at RepairClinic
  3. Call a technician to inspect the heat exchanger and venting before the furnace runs again

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 5 + 1 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.