Lennox Air Conditioner 401 Error Code

What the 401 code means

Long run time / possible low pressure (moderate alert), reported by the outdoor unit and shown on the iComfort Wi-Fi / S-series communicating thermostat on Lennox communicating air conditioners (e.g. SL18XC). Either the compressor ran more than 18 hours continuously on a single cooling demand, or refrigerant pressure in the system is low; the system is not locked out.

Likely causes

  1. Low refrigerant charge / refrigerant leak
  2. Low pressure switch trips during the long run → Shop the low pressure switch at RepairClinic
  3. Undersized unit or extreme heat load
  4. Restricted indoor airflow making the unit run continuously

How to fix it — step by step

  1. Replace a dirty indoor filter and make sure all vents are open
  2. Check that the outdoor coil is clean
  3. Have a technician check refrigerant charge and look for a leak if run times stay excessive