Lennox Air Conditioner 410 Error Code
What the 410 code means
Open low pressure switch (moderate alert), reported by the outdoor unit and shown on the iComfort Wi-Fi communicating thermostat on Lennox communicating air conditioners. The outdoor unit pressure is below the required limit; per Lennox the low pressure switch opens at 40 psig (system shuts down) and closes at 90 psig (system restarts).
Likely causes
- Low refrigerant charge / refrigerant leak
- Low indoor airflow (dirty filter, blower problem)
- Restriction in the refrigerant circuit
- Failed low pressure switch
How to fix it — step by step
- Replace a dirty indoor filter and confirm the indoor blower runs
- Turn the system off if the alert keeps returning
- Have a technician check refrigerant pressures and test the low pressure switch → Shop the low pressure switch at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Low pressure switch.
Parts that commonly fix the 410 code
- Low pressure switch - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.