Lennox Air Conditioner 405 Error Code

What the 405 code means

Compressor circuit open (critical alert), reported by the outdoor unit and shown on the iComfort Wi-Fi / S-series communicating thermostat on Lennox communicating air conditioners (e.g. SL18XC). The compressor circuit is open, for example from a power disconnection or an open fuse; the error clears after 1 normal compressor run cycle.

Likely causes

  1. Outdoor power disconnect open
  2. Open fuse or tripped breaker feeding the compressor
  3. Broken wire or loose connector in the compressor circuit
  4. Open compressor internal overload / winding

How to fix it — step by step

  1. Check the outdoor disconnect and the unit's breaker/fuses
  2. If power is present, have a technician trace the compressor circuit for an open wire, connector or winding → Shop the compressor at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 405 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Lennox Air Conditioner error codes

See all Lennox Air Conditioner codes & guides →