Lennox Air Conditioner 413 Error Code
What the 413 code means
High pressure switch lockout, reported by the outdoor unit control (DS15/DS13 compressor LED codes) and as alert code 413 on the iComfort Touch thermostat on Lennox XC21-series air conditioners (Unit Information, Table 10). Repeated high pressure trips have locked out the compressor.
Likely causes
- Repeated high pressure switch trips → Shop the high pressure switch at RepairClinic
- Dirty outdoor coil or failed outdoor fan driving head pressure up
- Refrigerant overcharge
How to fix it — step by step
- Turn the system off and clean the outdoor coil; confirm the outdoor fan runs
- Have a technician measure head pressure and correct the cause before resetting the lockout
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the High pressure switch.
Shop the High pressure switch at RepairClinic or Amazon
Also tied to this fault: Outdoor fan motor - Shop at RepairClinic or Amazon
Parts that commonly fix the 413 code
- High pressure switch - Shop at RepairClinic or Amazon
- Outdoor fan motor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number