Lennox Air Conditioner 411 Error Code
What the 411 code means
Low pressure switch strikes lockout (critical alert), reported by the outdoor unit and shown on the iComfort Wi-Fi communicating thermostat on Lennox communicating air conditioners. The low pressure switch has opened 5 times during one cooling cycle, so the thermostat has shut down the outdoor unit; Lennox directs checking system charge using approach and subcooling, and resetting via outdoor unit control test mode or resetting low-voltage power.
Likely causes
- Low refrigerant charge / refrigerant leak (most common)
- Repeated low airflow or restriction causing repeated low pressure trips
How to fix it — step by step
- Replace a dirty indoor filter and confirm indoor airflow
- Do not repeatedly reset the lockout
- Have a technician check charge by approach and subcooling, find any leak, and reset the lockout after repair
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Low pressure switch.
Parts that commonly fix the 411 code
- Low pressure switch - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.