Lennox Air Conditioner 411 Error Code

What the 411 code means

Low pressure switch strikes lockout (critical alert), reported by the outdoor unit and shown on the iComfort Wi-Fi communicating thermostat on Lennox communicating air conditioners. The low pressure switch has opened 5 times during one cooling cycle, so the thermostat has shut down the outdoor unit; Lennox directs checking system charge using approach and subcooling, and resetting via outdoor unit control test mode or resetting low-voltage power.

Likely causes

  1. Low refrigerant charge / refrigerant leak (most common)
  2. Repeated low airflow or restriction causing repeated low pressure trips

How to fix it — step by step

  1. Replace a dirty indoor filter and confirm indoor airflow
  2. Do not repeatedly reset the lockout
  3. Have a technician check charge by approach and subcooling, find any leak, and reset the lockout after repair

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 411 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.