Lennox Air Conditioner 414 Error Code
What the 414 code means
Discharge line temperature fault, reported by the outdoor unit control (DS15/DS13 compressor LED codes) and as alert code 414 on the iComfort Touch thermostat on Lennox XC21-series air conditioners (Unit Information, Table 10). Per Lennox, if the discharge line temperature exceeds 279°F (137°C) during compressor operation, the control de-energizes the compressor contactor output.
Likely causes
- Low refrigerant charge causing high discharge superheat
- High compression ratio / high head pressure
- Restricted refrigerant flow
How to fix it — step by step
- Turn the system off and let the compressor cool
- Have a technician check refrigerant charge and pressures and inspect for restrictions
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Discharge line temperature sensor.
Shop the Discharge line temperature sensor at RepairClinic or Amazon
Parts that commonly fix the 414 code
- Discharge line temperature sensor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.