Lennox Air Conditioner 407 Error Code
What the 407 code means
Open run circuit (critical alert), reported by the outdoor unit and shown on the iComfort Wi-Fi communicating thermostat on Lennox communicating air conditioners. The required amount of current is not passing through the RUN current transformer; the error clears after current is sensed in the RUN sensor, or 1 normal compressor run cycle, or after a power reset.
Likely causes
- Open compressor run winding or run circuit wiring → Shop the compressor at RepairClinic
- Failed run capacitor
- Contactor not closing or burnt contactor contacts
How to fix it — step by step
- Turn off power to the outdoor unit
- Have a technician test the run winding, run capacitor and contactor → Shop the run capacitor at RepairClinic
- Replace the failed component or repair the wiring
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Run capacitor.
Shop the Run capacitor at RepairClinic or Amazon
Also tied to this fault: Compressor contactor - Shop at RepairClinic or Amazon; Compressor - Shop at RepairClinic or Amazon
Parts that commonly fix the 407 code
- Run capacitor - Shop at RepairClinic or Amazon
- Compressor contactor - Shop at RepairClinic or Amazon
- Compressor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.