Lennox Air Conditioner 400 Error Code
What the 400 code means
Compressor internal overload has tripped (critical alert), reported by the outdoor unit and shown on the iComfort Wi-Fi / S-series communicating thermostat on Lennox communicating air conditioners (e.g. SL18XC). Thermostat demand Y1 is present but the compressor is not running; the error clears after current is sensed in both RUN and START sensors for at least 2 seconds, or after service is removed, or after a power reset.
Likely causes
- Compressor protector (internal overload) open
- High head pressure
- Compressor supply voltage problem
- Outdoor unit power disconnect open, or breaker/fuse open
- Low or high pressure switch open
- Compressor contactor failed to close
How to fix it — step by step
- Turn the system off and let the compressor cool → Shop the compressor at RepairClinic
- Check the outdoor disconnect and breaker, and clean the outdoor coil
- If the alert returns, have a technician check head pressure, compressor voltage and the contactor → Shop the compressor contactor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Compressor.
Shop the Compressor at RepairClinic or Amazon
Also tied to this fault: Compressor contactor - Shop at RepairClinic or Amazon
Parts that commonly fix the 400 code
- Compressor - Shop at RepairClinic or Amazon
- Compressor contactor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.