Carrier 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 18 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| 16 | System Communications Failure — communication with the User Interface (Infinity Control) is lost. The manual… | Loose or damaged ABCD communication wiring to the wall control, indoor or outdoor unit | › |
| 25 | Invalid Model Plug — the control does not detect a model plug or detects an invalid model plug, and the… | Model plug missing after a control board replacement | › |
| 31 | High Pressure Switch Open — a high-pressure switch trip, shown as 3 short and 1 long flashes on the amber… | Outdoor coil blocked by dirt, debris or ice restricting airflow | › |
| 32 | Low Pressure Switch or Discharge Temperature Switch Open — on this Carrier family code 32 is 3 short and 2… | Low refrigerant charge from a leak | › |
| 45 | Control Fault — the outdoor unit control board has failed and, in the manual's words, the control board needs… | Failed outdoor control board circuitry | › |
| 46 | Brown Out (230V) — line voltage was below 187 volts for at least 4 seconds, shown as 4 short and 6 long… | Utility voltage dip or brownout | › |
| 47 | No 230V at Unit — there is no 230 volts at the contactor when the indoor unit is powered and a cooling or… | Outdoor disconnect open, pulled or failed | › |
| 53 | Outdoor Air Temp Sensor Fault — the outdoor air sensor (OAT thermistor) is not reading or is out of range… | Failed or drifted outdoor air thermistor | › |
| 55 | Outdoor Coil Sensor Fault — the coil sensor (OCT thermistor) is not reading or is out of range, shown as 5… | Failed or drifted outdoor coil thermistor | › |
| 56 | Thermistors Out of Range — an improper relationship between the coil sensor and the outdoor air sensor, shown… | One thermistor drifted while the other reads correctly | › |
| 71 | Low Stage Thermal Cutout — compressor operation was detected then disappears while low stage demand exists… | Internal compressor overload tripping on heat or load | › |
| 72 | High Stage Thermal Cutout — compressor operation was detected then disappears while high stage demand exists… | Internal compressor overload tripping under high-stage load | › |
| 73 | Contactor Shorted — compressor voltage is sensed when no demand for compressor operation exists, shown as 7… | Contactor contacts welded or stuck closed | › |
| 74 | No 230V at Compressor — compressor voltage is not sensed when the compressor should be starting, shown as 7… | Contactor stuck open or failed coil | › |
| 81 | Low Stage Thermal Lockout — a thermal cutout has occurred in three consecutive low/high stage cycles, and low… | Repeated internal compressor overload trips (see code 71 causes) | › |
| 82 | High Stage Thermal Lockout — a thermal cutout has occurred in three consecutive high/low stage cycles, and… | Repeated high-stage compressor overload trips (see code 72 causes) | › |
| 83 | Low-Pressure Lockout — a low pressure switch trip has occurred during 3 consecutive cycles, and unit… | Refrigerant leak causing progressively low charge | › |
| 84 | High-Pressure Lockout — a high pressure switch trip has occurred during 3 consecutive cycles, and unit… | Outdoor fan motor failed or coil severely blocked/fouled | › |