Carrier Heat pump Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 18 codes covered.
Finding your model number: it is on the outdoor unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
25HNB6 / 25HNB9 Infinity (two-stage)
Codes flash on the control board's amber LED: short flashes (0.25 sec) are the first digit and long flashes (1 sec) the second - the manual's own example is 3 short + 2 long = code 32. The pattern repeats every 2.5 seconds.
| Code | What it means | Check first | |
|---|---|---|---|
| 16 | System Communications Failure — communication with the User Interface (Infinity Control) is lost. The manual… | Loose or damaged ABCD communication wiring to the wall control, indoor or outdoor unit | › |
| 25 | Invalid Model Plug — the control does not detect a model plug or detects an invalid model plug, and the… | Model plug missing after a control board replacement | › |
| 31 | High Pressure Switch Open — a high-pressure switch trip, shown as 3 short and 1 long flashes on the amber… | Outdoor coil blocked by dirt, debris or ice restricting airflow | › |
| 32 | Low Pressure Switch or Discharge Temperature Switch Open — on this Carrier family code 32 is 3 short and 2… | Low refrigerant charge from a leak | › |
| 45 | Control Fault — the outdoor unit control board has failed and, in the manual's words, the control board needs… | Failed outdoor control board circuitry | › |
| 46 | Brown Out (230V) — line voltage was below 187 volts for at least 4 seconds, shown as 4 short and 6 long… | Utility voltage dip or brownout | › |
| 47 | No 230V at Unit — there is no 230 volts at the contactor when the indoor unit is powered and a cooling or… | Outdoor disconnect open, pulled or failed | › |
| 53 | Outdoor Air Temp Sensor Fault — the outdoor air sensor (OAT thermistor) is not reading or is out of range… | Failed or drifted outdoor air thermistor | › |
| 55 | Outdoor Coil Sensor Fault — the coil sensor (OCT thermistor) is not reading or is out of range, shown as 5… | Failed or drifted outdoor coil thermistor | › |
| 56 | Thermistors Out of Range — an improper relationship between the coil sensor and the outdoor air sensor, shown… | One thermistor drifted while the other reads correctly | › |
| 71 | Low Stage Thermal Cutout — compressor operation was detected then disappears while low stage demand exists… | Internal compressor overload tripping on heat or load | › |
| 72 | High Stage Thermal Cutout — compressor operation was detected then disappears while high stage demand exists… | Internal compressor overload tripping under high-stage load | › |
| 73 | Contactor Shorted — compressor voltage is sensed when no demand for compressor operation exists, shown as 7… | Contactor contacts welded or stuck closed | › |
| 74 | No 230V at Compressor — compressor voltage is not sensed when the compressor should be starting, shown as 7… | Contactor stuck open or failed coil | › |
| 81 | Low Stage Thermal Lockout — a thermal cutout has occurred in three consecutive low/high stage cycles, and low… | Repeated internal compressor overload trips (see code 71 causes) | › |
| 82 | High Stage Thermal Lockout — a thermal cutout has occurred in three consecutive high/low stage cycles, and… | Repeated high-stage compressor overload trips (see code 72 causes) | › |
| 83 | Low-Pressure Lockout — a low pressure switch trip has occurred during 3 consecutive cycles, and unit… | Refrigerant leak causing progressively low charge | › |
| 84 | High-Pressure Lockout — a high pressure switch trip has occurred during 3 consecutive cycles, and unit… | Outdoor fan motor failed or coil severely blocked/fouled | › |
Common questions
How do I read a Carrier Infinity heat pump code?
Watch the amber LED on the outdoor control board. Short flashes (a quarter second) give the first digit and long flashes (one second) the second: 3 short + 2 long is code 32. The sequence pauses and repeats.
What does code 32 mean on a Carrier heat pump?
A low pressure switch or discharge temperature switch is open - the Infinity troubleshooting table's code 32. The control stops the compressor to protect it until the switch closes again.
Once you know the part you need, browse Carrier Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.