Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 71 Error Code
What the 71 code means
Low Stage Thermal Cutout — compressor operation was detected then disappears while low stage demand exists, shown as 7 short and 1 long flash. The manual lists possible causes as an internal compressor overload trip, or a start relay and capacitor held in circuit too long if installed. The board runs the outdoor fan and retries after a 15-minute delay while demand exists. A thermal cutout means the compressor overheated or lost operation mid-call; repeated cutouts escalate to the code 81 lockout.
Likely causes
- Internal compressor overload tripping on heat or load
- Start relay or run capacitor fault holding the start circuit in too long
- Low airflow or high refrigerant pressure overheating the compressor
- Loose compressor wiring or failing contactor dropping voltage
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Technician: after the compressor cools, check run/start capacitor values against their rating, test the start relay, measure compressor winding resistance and current draw, and check for the high-pressure or airflow conditions that overheat a compressor.
- Pinpoint: replace a failed Run capacitor, relay or Contactor if pinpointed; if electrics and pressures are correct and the internal overload keeps tripping, the compressor itself is pinpointed — EPA/technician-only repair.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Run capacitor.
Shop the Run capacitor at Amazon
Also tied to this fault: Contactor - Shop at Amazon
Parts that commonly fix the 71 code
- Run capacitor$5–$35Shop at Amazon
- Contactor$10–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.