Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 73 Error Code

What the 73 code means

Contactor Shorted — compressor voltage is sensed when no demand for compressor operation exists, shown as 7 short and 3 long flashes. The manual states the contactor may be stuck closed or there is a wiring error. This is a safety-relevant fault: the compressor can be powered when it should be off, so the unit may run uncommanded or fail to shut down. Do not keep resetting it — isolate power at the disconnect until the cause is found.

Likely causes

  1. Contactor contacts welded or stuck closed
  2. Wiring error or short feeding the compressor circuit
  3. Control board relay fault calling the contactor continuously
  4. Debris or insect damage preventing the contactor from opening

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. With demand OFF, a technician measures voltage at the compressor/contactor load side: voltage present with no call and no coil voltage pinpoints welded Contactor contacts; coil voltage present with no call pinpoints a control/wiring fault instead.
  5. Pinpoint: replace a stuck/welded Contactor; if the contactor opens correctly when its coil is de-energized, follow the coil-voltage result to the Control board or wiring error.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 73 code

Parts run $10–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump error codes

See all Carrier 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump codes & guides →