Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 55 Error Code
What the 55 code means
Outdoor Coil Sensor Fault — the coil sensor (OCT thermistor) is not reading or is out of range, shown as 5 short and 5 long flashes. The manual directs ohming out the sensor and checking wiring. If the OCT fails, low-ambient cooling is not allowed and, in heating, defrost occurs at each time interval but terminates after 5 minutes under the manual's default operation — so a failed coil sensor directly degrades defrost and can let the outdoor coil ice up.
Likely causes
- Failed or drifted outdoor coil thermistor
- Sensor loose or not secured tight on the stub tube
- Open, shorted or corroded sensor harness
- Damaged outdoor control board sensor input
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Confirm the OCT is secured tight on its stub tube as the manual illustrates, then with power OFF measure thermistor resistance against the manual's curve at the measured coil temperature and check harness continuity; compare with the OAT reading for plausibility.
- Pinpoint: replace the Thermistor/Defrost sensor if out of specification or physically loose/damaged; if sensor and harness are correct, pinpoint the outdoor Control board input — technician job. → Shop the defrost sensor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Defrost sensor - Shop at Amazon
Parts that commonly fix the 55 code
- Thermistor$25–$80Shop at Amazon
- Defrost sensor$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.