Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 74 Error Code

What the 74 code means

No 230V at Compressor — compressor voltage is not sensed when the compressor should be starting, shown as 7 short and 4 long flashes. The manual states the contactor may be stuck open or there is a wiring error. The control is commanding a start and power is present at the unit (otherwise code 47 would apply), but voltage does not reach the compressor, so the compressor never starts even though the outdoor fan may run.

Likely causes

  1. Contactor stuck open or failed coil
  2. Burnt or loose wiring between contactor and compressor
  3. Open compressor overload or damaged compressor terminals
  4. Control board not energizing the contactor coil

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. Technician: on a start call, measure 24V at the contactor coil — present coil voltage with no load-side 230V pinpoints the Contactor; absent coil voltage points back to the Control board or wiring; then check continuity through to the compressor terminals with power OFF.
  5. Pinpoint: replace the Contactor if it fails to close with correct coil voltage; otherwise repair the pinpointed wiring or Control board output — technician job. → Shop the contactor at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 74 code

Parts run $10–$35
  • Contactor$10–$35Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump error codes

See all Carrier 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump codes & guides →