Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 32 Error Code
What the 32 code means
Low Pressure Switch or Discharge Temperature Switch Open — on this Carrier family code 32 is 3 short and 2 long flashes (the manual's own worked example) and means a low-pressure switch or discharge temperature switch trip. The manual directs checking refrigerant charge and indoor air flow. The contactor is de-energized, the outdoor fan runs up to 15 minutes, and the control retries every 15 minutes while demand exists; repeated trips escalate to the code 83 lockout.
Likely causes
- Low refrigerant charge from a leak
- Low indoor airflow — clogged filter, closed registers or blower problem
- Iced indoor or outdoor coil restricting airflow
- Faulty low-pressure or discharge temperature switch or harness
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Replace a clogged indoor air filter and confirm the blower runs and registers are open; technician then checks charge with gauges, inspects for coil icing, and tests the low-pressure and discharge temperature switches and harnesses for continuity. → Shop the air filter at Amazon
- Pinpoint: if charge is low, leak-check and repair before recharging — EPA technician only; if charge and airflow are correct, the tripping switch or its harness is pinpointed for replacement.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air filter.
Also tied to this fault: Thermistor - Shop at Amazon
Parts that commonly fix the 32 code
- Air filter$5–$30Shop at Amazon
- Thermistor$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump error codes