Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 16 Error Code
What the 16 code means
System Communications Failure — communication with the User Interface (Infinity Control) is lost. The manual says to check wiring to the User Interface and to the indoor and outdoor units. Read as short/long flashes on the amber status LED on the outdoor control board and, on communicating systems, at the Infinity Control. Without communication the outdoor unit cannot receive a valid heat or cool demand, so the system will not run normally until the ABCD communication path is restored.
Likely causes
- Loose or damaged ABCD communication wiring to the wall control, indoor or outdoor unit
- Corroded or shorted communication terminals
- Failed outdoor control board communication circuit
- Incorrect wiring after a control or board replacement
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- With power restored only for testing by a qualified person, verify 24V control power and inspect the ABCD communication wiring end to end for loose, stripped, shorted-to-ground or crossed wires; a wiring fault that is corrected should allow the green COMM light to stay on and code 16 to clear.
- Pinpoint: if ABCD wiring, connections and 24V power all check good and 16 persists, the fault is in a communicating control or the outdoor Control board — replace the pinpointed board/control as a technician job and re-check communication. → Shop the control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Control board.
Parts that commonly fix the 16 code
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump error codes
See all Carrier 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump codes & guides →