Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump 56 Error Code
What the 56 code means
Thermistors Out of Range — an improper relationship between the coil sensor and the outdoor air sensor, shown as 5 short and 6 long flashes. The manual directs ohming out both sensors and checking wiring. The control continuously compares OAT and OCT; when their relationship is impossible for the operating mode, it flags 56 rather than a single failed sensor. Under the default operation, defrost occurs at each interval in heating and terminates after 5 minutes, reducing heating performance.
Likely causes
- One thermistor drifted while the other reads correctly
- Coil sensor mounted on the wrong tube or loose
- Outdoor air sensor touching sheet metal or mislocated
- Damaged or crossed sensor harness wiring
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- With power OFF, ohm out BOTH thermistors and compare each to the manual's resistance-versus-temperature curve at their actual temperatures; the sensor that disagrees with its real temperature is the culprit, and verify each sensor is mounted in its correct location. → Shop the thermistor at Amazon
- Pinpoint: replace the out-of-specification Thermistor or correct its mounting; if both sensors and wiring test correct, the outdoor Control board comparison input is pinpointed for a technician.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Defrost sensor - Shop at Amazon
Parts that commonly fix the 56 code
- Thermistor$25–$80Shop at Amazon
- Defrost sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Carrier Heat pump 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump error codes
See all Carrier 25HNB6 / 25HNB9 Infinity 2-Stage Heat Pump codes & guides →