Trane Air Conditioner Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 21 problems covered.
Shop Trane Air Conditioner parts at RepairClinic or Amazon
All Air Conditioner codes across brands →
Not sure of the code? Tap along with it
If your Trane Air Conditioner blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your rhythm: -
Finding your model number: it is on the unit's rating plate.
ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes
All Trane ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes codes & guides → (9 covered)
- 102 — Y2 without Y1 miswire (24V mode only), shown as ERR 102 on the ComfortLink communicating control and as 10 flashes of the fault LED on the…
- 113 — Liquid pressure sensor fault (out of range — open or shorted), shown as ERR 113 on the ComfortLink communicating control and as 12 flashes…
- 114 (14 flashes) — Bad or missing personality module (PM) — bad data in PM with no local copy, unit not operational — shown as ERR 114 on the ComfortLink…
- 67 (5 flashes) — Temperature sensor fault — ambient temperature sensor fault (out of range, open or shorted), shown as ERR 67 on the ComfortLink…
- 67 (6 flashes) — Temperature sensor fault — coil temperature sensor fault (out of range, open or shorted), shown as ERR 67 on the ComfortLink communicating…
- 68 (2 flashes) — Defrost fault A (out of range — shorted), shown as ERR 68 on the ComfortLink communicating control and as 2 flashes of the fault LED on the…
- 68 (3 flashes) — Defrost fault B and/or C, shown as ERR 68 on the ComfortLink communicating control and as 3 flashes of the fault LED on the outdoor unit…
- 79 — Low pressure cut-out (LPCO) fault, shown as ERR 79 on the ComfortLink communicating control and as 7 flashes of the fault LED on the…
- 80 — High pressure cut-out (HPCO) / high pressure monitor fault, shown as ERR 80 on the ComfortLink communicating control and as 17 flashes of…
Demand defrost control — A4HP4/4TWA split heat pump
All Trane Demand defrost control — A4HP4/4TWA split heat pump codes & guides → (6 covered)
- Defrost board 1 flash — Ambient temperature sensor is out of range (open/shorted), flashed by the fault LED on the demand defrost control board inside the outdoor…
- Defrost board 2 flashes — Coil temperature sensor is out of range (open/shorted), flashed by the fault LED on the demand defrost control board inside the outdoor…
- Defrost board 3 flashes — Low pressure switch is open, flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane…
- Defrost board 4 flashes — Hard lockout, flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split heat pump…
- Defrost board 6 flashes — Defrost cycles too close together / heating short-cycle fault, flashed by the fault LED on the demand defrost control board inside the…
- Defrost board 9 flashes — Low ambient soft lockout, flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split…
Other codes & guides
- AC leaking water inside — On a Trane split system, condensation forms at the indoor evaporator coil, drips into the drain pan, and exits through a PVC condensate…
- AC not cooling — Trane's pre-service-call checks for a system that runs without cooling are deliberately basic: a thermostat still in heating mode or set…
- AC short cycling — Trane draws a careful line here: short runs are not automatically short cycling. A properly sized system may run only 3 to 5 minutes in…
- AC won't turn on — For a Trane system that will not start, Trane's own guidance is to work the simple end first: the thermostat may still be in heating mode…
- Condenser fan not spinning — The condenser fan in the outdoor unit moves air across the coil so refrigerant can shed the heat it collected indoors. When it stops, head…
- Frozen evaporator coil — Trane publishes a top-five list for frozen evaporator coils, and four of the five are airflow problems: a dirty air filter, a dirty…