Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump Defrost board 2 flashes

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Coil temperature sensor is out of range (open/shorted), flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split heat pump (A4HP4 / 4TWA series, Service Facts A4HP4017D-SF). The control initiates a 15-minute forced defrost after every 60 minutes of runtime as a fallback.

Likely causes

  1. Open or shorted outdoor coil temperature sensor → Shop the outdoor coil temperature sensor at RepairClinic
  2. Damaged sensor wiring or sensor displaced from the coil

How to fix it — step by step

  1. Turn off power to the outdoor unit
  2. Have a technician measure the sensor resistance against the thermistor table and check its mounting on the coil
  3. Replace the sensor if out of range

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.