Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump Defrost board 6 flashes
What it should look like on your machine
then it repeats
6 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Defrost cycles too close together / heating short-cycle fault, flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split heat pump (A4HP4 / 4TWA series, Service Facts A4HP4017D-SF). The system follows 10 adaptive-time heating cycles and then returns to demand defrost.
Likely causes
- Condenser fan motor failure causing short defrost/heating cycles
- Low refrigerant charge
- Faulty coil or ambient sensor readings driving false defrost demand
How to fix it — step by step
- Turn off power to the outdoor unit
- Have a technician check the outdoor fan motor, refrigerant charge and both defrost sensors
- Repair the cause; the control returns to demand defrost after the adaptive cycles if operation normalizes
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor (condenser) fan motor.
Shop the Outdoor (condenser) fan motor at RepairClinic or Amazon
Also tied to this fault: Outdoor coil temperature sensor - Shop at RepairClinic or Amazon
Parts that commonly fix it
- Outdoor (condenser) fan motor - Shop at RepairClinic or Amazon
- Outdoor coil temperature sensor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump problems
- Defrost board 9 flashes
- Defrost board 1 flash
- Defrost board 2 flashes
- Defrost board 3 flashes
- Defrost board 4 flashes
See all Trane Demand defrost control — A4HP4/4TWA split heat pump codes & guides →