Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump Defrost board 9 flashes

What it should look like on your machine

then it repeats

9 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Low ambient soft lockout, flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split heat pump (A4HP4 / 4TWA series, Service Facts A4HP4017D-SF). Outdoor temperature is below -12°F (lockout off at -12°F / on again at -3°F per the Service Facts notes).

Likely causes

  1. Outdoor temperature genuinely below the heat pump's low ambient lockout point
  2. Ambient sensor reading colder than actual temperature

How to fix it — step by step

  1. If it is extremely cold, this is protective operation — use auxiliary/emergency heat until temperatures rise
  2. If the temperature is not that cold, have a technician test the ambient sensor against the thermistor table

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump problems

See all Trane Demand defrost control — A4HP4/4TWA split heat pump codes & guides →