Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes 79 Error Code

What it should look like on your machine

then it repeats

7 flashes - then the pattern repeats. Count along with your machine and compare.

What the 79 code means

Low pressure cut-out (LPCO) fault, shown as ERR 79 on the ComfortLink communicating control and as 7 flashes of the fault LED on the outdoor unit control board of a Trane communicating outdoor unit, per Trane's Alert Code Addendum 18-HD32D2-10. The low pressure cut-out opened outside of a defrost cycle, causing a heat/cool lockout (hard lockout versions require cycling power to reset).

Likely causes

  1. Low refrigerant charge / refrigerant leak
  2. Restriction in the refrigerant circuit
  3. Low indoor airflow causing low suction pressure
  4. Failed low pressure cut-out switch

How to fix it — step by step

  1. Replace a dirty indoor filter and confirm indoor blower operation
  2. Turn the system off instead of repeatedly cycling power
  3. Have a technician check refrigerant pressures, test the LPCO switch and find any leak → Shop the low pressure cut-out switch (lpco) at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 79 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes error codes

See all Trane ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes codes & guides →