Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes 102 Error Code
What it should look like on your machine
then it repeats
10 flashes - then the pattern repeats. Count along with your machine and compare.
What the 102 code means
Y2 without Y1 miswire (24V mode only), shown as ERR 102 on the ComfortLink communicating control and as 10 flashes of the fault LED on the outdoor unit control board of a Trane communicating outdoor unit, per Trane's Alert Code Addendum 18-HD32D2-10. The control is receiving a second-stage (Y2) demand with no first-stage (Y1) demand.
Likely causes
- Thermostat or indoor unit wiring error between Y1 and Y2
- Y1 wire open or landed on the wrong terminal
How to fix it — step by step
- Turn off power to the system
- Have a technician check the Y1/Y2 wiring at the thermostat, indoor unit and outdoor unit against the wiring diagram
- Correct the wiring and retest both stages of cooling
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable opening the machine up, a repair shop is the next step.
Parts that commonly fix the 102 code
No specific replacement part is documented for this fault. If the checks above do not clear it, the machine likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes error codes
See all Trane ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes codes & guides →