Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump Defrost board 4 flashes

What it should look like on your machine

then it repeats

4 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Hard lockout, flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split heat pump (A4HP4 / 4TWA series, Service Facts A4HP4017D-SF). It occurs after the 9th trip of the low pressure cut-out and can only be cleared with a low-voltage power cycle.

Likely causes

  1. Repeated low pressure cut-out trips (9 trips)
  2. Unrepaired low charge, restriction or airflow problem causing the earlier trips

How to fix it — step by step

  1. Do not just cycle power to clear it — the underlying low-pressure cause must be found first
  2. Have a technician check refrigerant charge and pressures, airflow and the LPCO circuit → Shop the low pressure switch (lpco) at RepairClinic
  3. Cycle low-voltage power only after the cause is repaired to clear the lockout

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump problems

See all Trane Demand defrost control — A4HP4/4TWA split heat pump codes & guides →