Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes 67 (5 flashes)

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Temperature sensor fault — ambient temperature sensor fault (out of range, open or shorted), shown as ERR 67 on the ComfortLink communicating control and as 5 flashes of the fault LED on the outdoor unit control board of a Trane communicating (XL/XV) outdoor unit, per Trane's Alert Code Addendum 18-HD32D2-10.

Likely causes

  1. Open or shorted outdoor ambient temperature sensor → Shop the outdoor ambient temperature sensor at RepairClinic
  2. Damaged sensor wiring or loose connection at the outdoor control

How to fix it — step by step

  1. Turn off power to the outdoor unit
  2. Inspect the ambient sensor and wiring at the outdoor control
  3. Have a technician ohm out the sensor and replace it if out of range

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes problems

See all Trane ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes codes & guides →