Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes 80 Error Code

What it should look like on your machine

then it repeats

17 flashes - then the pattern repeats. Count along with your machine and compare.

What the 80 code means

High pressure cut-out (HPCO) / high pressure monitor fault, shown as ERR 80 on the ComfortLink communicating control and as 17 flashes of the fault LED on the outdoor unit control board of a Trane communicating outdoor unit, per Trane's Alert Code Addendum 18-HD32D2-10. Hard-lockout versions require cycling power to reset.

Likely causes

  1. Dirty or blocked outdoor coil
  2. Outdoor fan not running
  3. Refrigerant overcharge
  4. Failed high pressure cut-out switch

How to fix it — step by step

  1. Turn the system off and clean debris from the outdoor coil
  2. Confirm the outdoor fan runs on a cooling call
  3. Have a technician check refrigerant pressures and the HPCO switch before resetting a hard lockout → Shop the high pressure cut-out switch (hpco) at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 80 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Air Conditioner ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes error codes

See all Trane ComfortLink communicating outdoor unit (XL/XV) — ERR alert codes codes & guides →