Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump Defrost board 1 flash

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Ambient temperature sensor is out of range (open/shorted), flashed by the fault LED on the demand defrost control board inside the outdoor unit control box of a Trane split heat pump (A4HP4 / 4TWA series, Service Facts A4HP4017D-SF). The control initiates defrost after every 60 minutes of runtime as a fallback.

Likely causes

  1. Open or shorted outdoor ambient temperature sensor → Shop the outdoor ambient temperature sensor at RepairClinic
  2. Damaged sensor wiring

How to fix it — step by step

  1. Turn off power to the outdoor unit
  2. Have a technician measure the sensor resistance against the defrost control thermistor table in the Service Facts
  3. Replace the sensor if its resistance does not match the chart

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Air Conditioner Demand defrost control — A4HP4/4TWA split heat pump problems

See all Trane Demand defrost control — A4HP4/4TWA split heat pump codes & guides →