Rheem Seven-segment display — R95P platform Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 16 codes covered.
Shop Rheem Seven-segment display — R95P platform parts at RepairClinic or Amazon
- 0 — Standby on Rheem furnaces with the 7-segment diagnostic display (including R95P models). This is a normal status, not a fault — the furnace…
- 10 — One-hour lockout on Rheem furnaces with the 7-segment diagnostic display. The control locked out after repeated ignition or flame failures…
- 11 — Failed ignition on Rheem furnaces with the 7-segment diagnostic display. The burners did not light during the ignition trial.
- 12 — Low flame sense on Rheem furnaces with the 7-segment diagnostic display. Flame is present but the flame signal is too weak.
- 13 — Flame lost on Rheem furnaces with the 7-segment diagnostic display. Flame was established and then lost during the heating cycle; five…
- 14 — Unexpected flame on Rheem furnaces with the 7-segment diagnostic display. Flame is sensed when the gas valve should be closed — shut down…
- 20 — Twinning fault on Rheem furnaces with the 7-segment diagnostic display. This applies to twinned furnace installations where the two…
- 22 — Main limit open on Rheem furnaces with the 7-segment diagnostic display. The main limit safety opened from overheating, most often from…
- 26 — Line and neutral reversed on Rheem furnaces with the 7-segment diagnostic display. The 115V supply polarity to the control is reversed.
- 33 — Manual reset limit control (MRLC), also called the rollout switch, is open on Rheem furnaces with the 7-segment diagnostic display. This is…
- 55 — Pressure switch stuck closed when it should be open on Rheem furnaces with the 7-segment diagnostic display. The control will not start the…
- 57 — Pressure switch stuck open when it should be closed on Rheem furnaces with the 7-segment diagnostic display. The inducer ran but draft was…
- 58 — Water sense circuit open on Rheem R95P furnaces with the 7-segment diagnostic display. The water level sensing circuit for the condensate…
- 59 — Water sensed (blocked drain) on Rheem furnaces with the 7-segment diagnostic display. The water level sensor detected condensate backing…
- 61 — Blower fault — blower unable to run — on Rheem furnaces with the 7-segment diagnostic display. The control declared a non-operational…
- 93 — Internal control fault on Rheem furnaces with the 7-segment diagnostic display. The integrated furnace control has failed internally.