Rheem Furnace Seven-segment display — R95P platform 57 Error Code
What the 57 code means
Pressure switch stuck open when it should be closed on Rheem furnaces with the 7-segment diagnostic display. The inducer ran but draft was not proven.
Likely causes
- blocked vent or excessive vent length/elbows
- clogged condensate drain
- weak inducer motor → Shop the inducer motor at RepairClinic
- blocked heat exchanger or faulty pressure switch → Shop the pressure switch at RepairClinic
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at RepairClinic or Amazon
Also tied to this fault: inducer motor - Shop at RepairClinic or Amazon
Parts that commonly fix the 57 code
- pressure switch - Shop at RepairClinic or Amazon
- inducer motor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.