Rheem Air Conditioner Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 21 codes covered.
Shop Rheem Air Conditioner parts at RepairClinic or Amazon
All Air Conditioner codes across brands →
Finding your model number: it is on the unit's rating plate.
- A001_O — Model data configuration error, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor Control…
- A100_O — Communications lost with indoor unit, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A906_O — Inverter fault — AC input overvoltage, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A910_O — Inverter fault — lost rotor position, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A915_O — Inverter fault — communication fault, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A924_O — Inverter fault — board temperature, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A929_O — 240V missing or inverter communication failure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal…
- A953_O — Coil temperature thermistor failure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A954_O — Suction temperature thermistor failure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A956_O — Suction pressure sensor failure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A957_O — Low refrigerant pressure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor Control…
- A958_O — High refrigerant pressure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor Control…
- A960_O — Compressor locked rotor — lockout, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor…
- A975_O — Contactor stuck on, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor Control (UODC) of a…
- A979_O — Compressor over/under speed, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor Control…
- AC leaking water inside — Water around a Rheem furnace or air handler almost always means condensate is not leaving: the drain line is clogged, or the drain pan is…
- AC not cooling — Rheem's troubleshooting guidance for a system that runs without cooling separates the owner's checks from the sealed-system causes. On the…
- AC short cycling — Rheem builds short-cycle detection into its controls: the anti-short-cycle timer shows as a flashing cooling code, and Rheem's fault list…
- AC won't turn on — Rheem's service documentation for a unit that will not run starts with power and protection, not parts: power off or loose electrical…
- Condenser fan not spinning — First, a Rheem-specific caution from its own troubleshooting guidance: the outdoor fan only runs when the system is actively cooling, so a…
- Frozen evaporator coil — Rheem's diagnostic literature for an iced indoor coil reads like a checklist of airflow and charge: check evaporator airflow (coil…