Rheem Air Conditioner AC not cooling

What this problem usually means

Rheem's troubleshooting guidance for a system that runs without cooling separates the owner's checks from the sealed-system causes. On the owner side: a thermostat not actually set to cooling, dirty or clogged air filters, and poor indoor air circulation. On the technician side: an improperly charged system, air or moisture contaminating the refrigerant circuit, a faulty indoor TXV, or a unit simply too small for the load. The pattern to report is whether airflow at the vents is strong but warm (points to the refrigerant side) or weak (points to filters and circulation first).

Likely causes

  1. Thermostat not set to cooling, or set incorrectly
  2. Dirty or clogged air filter
  3. Poor indoor air circulation — blocked returns or closed vents
  4. Improper refrigerant charge, or air/moisture in the sealed system
  5. Faulty TXV (metering device) or an undersized unit for the home's load

How to fix it — step by step

  1. Set the thermostat to Cool and Auto, with the setpoint clearly below room temperature, and wait several minutes for the system to respond → Shop the thermostat at RepairClinic
  2. Turn the system off and replace a dirty air filter → Shop the air filter at RepairClinic
  3. Open all supply and return vents and clear anything blocking the returns to restore circulation
  4. Clear debris from around the outdoor unit so the condenser can reject heat
  5. Stop at the sealed system: Rheem's guidance assigns refrigerant charge, contamination and TXV faults to an authorized service technician → Shop the txv (thermal expansion valve) at RepairClinic → Shop the refrigerant at RepairClinic
  6. If the system has never kept up on hot afternoons, raise sizing with the technician rather than repeatedly recharging

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.