Rheem Air Conditioner Frozen evaporator coil
What this problem usually means
Rheem's diagnostic literature for an iced indoor coil reads like a checklist of airflow and charge: check evaporator airflow (coil blockages or the return air filter), check ductwork and registers for blockage, check for an excessively low thermostat setting, and check suction pressure for low charge. Rheem service guidance adds a filter subtlety owners miss — a filter with excessive resistance, or more than one filter installed in the return, can starve the coil just as surely as a dirty one. The outdoor module's long-run ALERT code is often the first recorded sign, listing a frozen coil among its causes.
Likely causes
- Dirty, clogged, overly restrictive, or doubled-up air filters starving airflow → Shop the air filter at RepairClinic
- Blocked ductwork or closed registers reducing air across the coil
- Thermostat set excessively low, keeping the coil below freezing for long stretches
- Low refrigerant charge dropping suction pressure and coil temperature
- Faulty metering device (TXV) underfeeding the coil → Shop the txv (thermal expansion valve) at RepairClinic
How to fix it — step by step
- Turn cooling Off when you find ice on the coil or the suction line; do not chip the ice and do not keep running the system
- Set the fan to On to thaw the coil with room air, and protect the floor below for meltwater
- Replace the filter once thawed — with a standard-efficiency filter, and only one filter in the return path
- Open all registers and clear blocked returns and duct outlets
- Raise the setpoint to a reasonable level rather than running the thermostat at its minimum
- Call a Rheem contractor if the coil refreezes with airflow restored — low charge and metering-device faults need gauges, and refrigerant work requires certification → Shop the refrigerant at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the air filter.
Shop the air filter at RepairClinic or Amazon
Also tied to this fault: evaporator coil - Shop at RepairClinic or Amazon; refrigerant - Shop at RepairClinic or Amazon; TXV (thermal expansion valve) - Shop at RepairClinic or Amazon
Parts that commonly fix it
- air filter - Shop at RepairClinic or Amazon
- evaporator coil - Shop at RepairClinic or Amazon
- refrigerant - Shop at RepairClinic or Amazon
- TXV (thermal expansion valve) - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.