Rheem Air Conditioner AC leaking water inside

What this problem usually means

Water around a Rheem furnace or air handler almost always means condensate is not leaving: the drain line is clogged, or the drain pan is full, cracked or overflowing. Rheem and Ruud equipment shares this failure pattern (the two brands are built by the same company), along with the supporting cast — run capacitors, contactors and drain problems are their most common service items. A frozen coil is the delayed version of the same leak: ice melts, the pan cannot keep up, and water appears hours after the cooling problem started. If water is reaching drywall or a ceiling, the system should be shut off first and questions asked second.

Likely causes

  1. Clogged condensate drain line backing water into the pan → Shop the condensate drain line at RepairClinic
  2. Cracked, rusted or overflowing drain pan → Shop the drain pan at RepairClinic
  3. Frozen evaporator coil thawing faster than the drain can handle
  4. Dirty air filter causing the freeze-up behind the meltwater
  5. Failed condensate pump on systems that pump condensate to a remote drain

How to fix it — step by step

  1. Turn the system off if water is pooling near the air handler or reaching drywall or ceilings, and mop or wet-vac the water up
  2. Check the air filter and look for ice on the coil or lines; thaw a frozen coil completely before restarting → Shop the air filter at RepairClinic
  3. Clear the condensate line with a wet/dry vacuum at its outdoor exit, then pour vinegar into the indoor access point to slow algae regrowth
  4. Inspect the pan for cracks and standing water, and confirm a condensate pump (if fitted) is plugged in and running → Shop the condensate pump at RepairClinic
  5. On an EcoNet-equipped system, photograph any alert shown — Rheem dealers use those messages, and a photo preserves it before a reset clears it
  6. Call a Rheem contractor if the leak returns after the drain is cleared, the pan is damaged, or the coil keeps refreezing

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.